Process Control and Instrumentation Quiz 1
1 / 50
A typical example of a physical system with under damped characteristic is a______?
2 / 50
A negative gain margin expressed in decibels means a/an _____ system?
3 / 50
_______ is undesirable in thermocouples used in industries ?
4 / 50
A photo electric device in which the resistance of the metal is directly proportional to the light striking on it, is known as photo-conductive cell. Photoelectric transducers are used for the measurement of those parameters, which can be used to produce variation in________?
5 / 50
Bimetal strips are not used in_________?
6 / 50
Compositional analysis of flue gas coming out of a furnace in respect of O2 and CO2% can be continuously done by a/an_____?
7 / 50
Compositional analysis of _______ is done using mass spectrometer?
8 / 50
Composition of alloys can be determined by __________?
9 / 50
_______ controller has the maximum stabilising time?
10 / 50
Composition of natural gas is determined by the__________?
11 / 50
A pyrheliometer is an instrument used for measuring the__________?
12 / 50
A non-linear system will have ______ steady state values?
13 / 50
_____ stability method uses open loop transfer function?
14 / 50
All the thermocouples used for temperature measurement use dissimilar metal _________?
15 / 50
Accurate temperature measurement performance of a radiation pyrometer cannot be affected, if the ?
16 / 50
?A control system is unstable, if the open loop frequency response exhibits an amplitude ratio exceeding unity at the crossover frequency.? This is ________ criterion?
17 / 50
An aneroid barometer measures the ______ pressure?
18 / 50
According to Bode stability criterion, a system is unstable, if the open loop frequency response exhibits an amplitude ratio exceeding unity at frequency for which phase lag is__________?
19 / 50
A mercury barometer measures the ______ pressure?
20 / 50
A mercury thermometer cannot be used to measure the temperature below the freezing point of mercury, which is ______ ?C?
21 / 50
Bode stability method uses _____ loop transfer function?
22 / 50
A bimetallic thermometer as compared to industrial mercury in glass thermometer has almost the same__________?
23 / 50
________ thermometer cannot measure sub-zero (< 0? C) temperature ?
24 / 50
A first order system with unity gain and time constant ? is subjected to a sinusoidal input of frequency w = 1/?. The amplitude ratio for this system is_______?
25 / 50
A stable system is the one_____?
26 / 50
_____ are analysed using a Polarograph?
27 / 50
Concentration of sugar solution can be determined by the___________?
28 / 50
A manometer measures the ______ pressure?
29 / 50
A constant volume gas thermometer employing _______ is used to measure sub-zero (i.e., < 0?C) temperature?
30 / 50
A pyranometer is an instrument used for measuring the_____?
31 / 50
Cascade control means ________?
32 / 50
An amplitude ratio of 0.1 corresponds to ______ decibels?
33 / 50
Change of angle of refraction with composition comprises the working principle of a_____?
34 / 50
Characteristic equation is the denominator of _____ loop transfer function?
35 / 50
A magnetic flowmeter is__________?
36 / 50
Bourdon tube is never made of_________?
37 / 50
A system with transfer function [(2S/4S) + 1] is of ______ order?
38 / 50
Bode diagram are generated from output response of the system subjected to which of the following input ?
39 / 50
A first order system with a time constant of 1 min is subjected to frequency response analysis. At an input frequency of 1 radian/min, the phase shift is_______?
40 / 50
A proportional controller with a gain of Kc is used to control a first order process. The offset will increase, if_________?
41 / 50
Configuration of Bourdon spring tube is never made of ______ shape?
42 / 50
A sinusoidal variation in the input passing through a linear first order system __________?
43 / 50
______ is an example of distributed parameter system ?
44 / 50
Continuous flue gas analyser makes use of paramagnetic properties of some of its constituents, which move towards the strongest part of the magnetic field thus displacing diamagnetic gases. Which of the following gases is diamagnetic ?
45 / 50
A barometer measures the ______ pressure?
46 / 50
A system with a double pole at the origin is unstable since the corresponding term in the time domain_________?
47 / 50
A non-linear chemical system is exemplified by a/an__________?
48 / 50
A bolometer is ___________?
49 / 50
A simple pitot tube measures the_____?
50 / 50
_____ is the static characteristics of an instrument?
Provide Your Information
Your score is
The average score is 0%
Restart quiz